WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: NOVEMBER ISSUE PUBLISHED
  • NOVEMBER 2024 Issue has been successfully launched on NOVEMBER 2024.

Abstract

BIOANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF AMLODIPINE BESYLATE BY USING RP-HPLC ON HUMAN PLASMA

Mahendra D.*

ABSTRACT

A simple, sensitive, rapid and precise bioanalytical RP-HPLC method was developed for estimation of Amlodipine besylate in human plasma. The work carried out on Shimadzu LC-2010 CHT HPLC system equipped with Waters C18 (1504.6 mm,5) column with mobile phase containing 10 mMpotassium dihydrogen phosphate buffer, pH 6.4: Acetonitrile: Methanol in the ratio 20:70:10 v/v/v (1ml/min.)and detectionwavelength 238 nm. The retention time of Amlodipine besylate was found to be 4.1 min. The developed bioanalytical method was found to be linear in concentration range of 24-48 ng/ml (R2= 0.9913). The precision study revealed that the percentage cumulative variation was within acceptable limit and accuracystudy showed the value of mean percent recovery between 100.41-103.80 %. The Amlodipine besylate was stable in human plasma at different storage conditions. The validation parameters of the method met the acceptance criteria. Sufficient stability of both LQC and HQC was shown to allow for completion of sample analysis in clinical trials. From the results, we can conclude that developed bioanalytical method can be used for routine analysis of Amlodipine besylate.

Keywords: Bioanalytical method, Amlodipine besylate, Human plasma, RP-HPLC method, Validation.


[Download Article]     [Download Certifiate]

Call for Paper

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Online Submission

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Email & SMS Alert

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More