WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: NOVEMBER ISSUE PUBLISHED
  • NOVEMBER 2024 Issue has been successfully launched on NOVEMBER 2024.

Abstract

ACCURACY OF WORKING LENGTH DETERMINATION USING IOPA GRID TECHNIQUE AND APEX LOCATOR: AN IN VIVO STUDY

Himanshu Sharma, Anil Kumar Sharma, Rashmi R. Acharya, Megha Gupta, Akshay Sharma*, Himanshu Thukral and Dhruv Gupta

ABSTRACT

Background: The study consisted of 40 teeth which comprised of 10 maxillary incisors, 7 mandibular incisors, 5 maxillary canines, 2 mandibular canines, 3 maxillary premolars, 4 maxillary molars and 9 mandibular molars (68 canals). The working length of these teeth were measured by apex locator (Morita ZX), confirmed by a diagnostic radiograph and tooth length by IOPA on which a grid was fixed with a salotape. The radiographs were taken by paralleling technique with the help of a cone beam indicating device. These teeth were further divided into three groups and correction factors of 1.5 mm, 1 mm and 0.5 mm were applied to the values of the tooth length obtained by the IOPA grid technique according to the criteria given by Morfis et al. It was discovered in the process that maxillary and mandibular canines couldn’t be put into any of the groups so a fourth group was made which consisted of these teeth and probability of the correct correction factor was analysed. Result: A Statistical analysis of the data indicated that the 49% of the cases in whole study showed 1 mm as the correct correction factor to be deducted from the tooth length measured by the IOPA grid. Conclusion: IOPA grid can prove as substitute in maximum number of cases in case of absence of a Apex locator.

Keywords: .


[Download Article]     [Download Certifiate]

Call for Paper

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Online Submission

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Email & SMS Alert

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More