WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: NOVEMBER ISSUE PUBLISHED
  • NOVEMBER 2024 Issue has been successfully launched on NOVEMBER 2024.

Abstract

DEVELOPMENT AND VALIDATION OF LC-MS/MS METHOD FOR THE ESTIMATION OF NEBIVOLOL IN HUMAN PLASMA

Praveen Kumar Dasari* and Srinivasa Rao Dorapaneedi

ABSTRACT

In the present work, determination of Nebivolol in human plasma was developed and validated with a large calibration curve range (10 - 4000 pg/mL) by specific, sensitive, an accurate liquid chromatography-tandem mass spectrometry method. The analyte from the human plasma was extracted from Liquid-liquid extraction method. The separation was achieved using Xbridge Zorbax Eclipse XDB - C18 (150 x 4.6 mm, 5 μ) column with Acetonitrile: 20mM Ammonium formate (pH-3.0) (50: 50, v/v) as a mobile phase. A flow rate of 1.0 mL/min and run time 10.0 min was used for the chromatographic analysis of Nebivolol. Sensitivity of this method was found to be 10pg/mL. The analyte was analyzed by mass spectrometry in the multiple reaction monitoring modes. The precursor-product ion m/z was 406.2  151.0 m/z and Nebivolol-D4 was 410.2  151.0 m/z were used for quantification of an analyte and its IS. The method was validated in terms of accuracy, precision, selectivity, recovery, freeze-thaw stability, bench-top stability, stock solution stability and re-injection reproducibility. Within- and between-batch precision was obtained within the range 0.7 to 8.2. The mean recovery for drug was obtained 87.71% where as the mean recovery of IS was 84.97%. The % RSD value at higher concentration and lower concentration in all stability experiments was within 15%. This method is free from ion suppression, ion enhancement and any type of abnormal ionization.

Keywords: Nebivolol, LC-MS/MS, Human Plasma.


[Download Article]     [Download Certifiate]

Call for Paper

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Online Submission

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Email & SMS Alert

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More