UV SPECTROPHOTOMETRIC ESTIMATION OF DIACEREIN IN API AND CAPSULE DOSAGE FORM USING AREA UNDER CURVE METHOD
Dr. Hemant Kumar Jain* and Ravi S. Kadam
ABSTRACT
The aim of present work was to develop an accurate, precise,
reproducible and economical UV spectrophotometric Area Under
Curve method for estimation ofDiacerein. The Area Under Curve of
UV spectrum was calculated between 246 to 266 nm and a simple
method was developed.The method has followed linearity in the range
of 2-10μg/ml.The value of correlation coefficient was 0.9976. This
method was validated as per ICH guideline Q2 (R1).Satisfactory
values of Percent relative standard deviation for the intra-day and interday
precision indicated that method is precise. Results of the recovery
studies (99.73% to 101.99%) showed accuracy of the method. LOD
and LOQ were calculated as 0.70μg/ml and 2.13μg/ml,respectively.
The developed method can be used for routine estimation of Diacerein
in bulk and Capsule dosage forms.
Keywords: Diacerein, Area under Curve, UV spectrophotometry, Validation.