WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: NOVEMBER ISSUE PUBLISHED
  • NOVEMBER 2024 Issue has been successfully launched on NOVEMBER 2024.

Abstract

METHOD DEVELOPMENT AND VALIDATION STUDY FOR QUANTITATIVE DETERMINATION OF CHLORO AND SULFIDE COMPOUND GENOTOXIC IMPURITIES IN ESOMEPRAZOLE ACTIVE PHARMACEUTICAL INGREDIENT (API) BY LC/MS/MS

Noor Shabana and K.Dayananda Reddy*

ABSTRACT

A simple, sensitive and rapid LC- ESI-MS/MS method has been developed and validated for the trace analysis (>1 ppm level) of 2-chloromethyl-4-methanesulfonyl-3, 5-dimethylpyridine hydrochloride (chloro) and 2-({[3,5-dimethyl-4-(methylsulfonyl)pyridi-2-yl]methyl} sulfanyl)-5-methoxy-1H-Benzimidazole (sulfide) compounds are genotoxic impurities, in esomeprazole magnesium drug. The chromatographic separation was achieved on a Hypersil BDS C8 (50 x 4.6mm, 3μm) column using a mobile phase consisting of 5mM ammonium acetate, methanol and acetonitrile (65:20:15, v/v/v) at flow rate of 0.6 mL/min. The API-4000 LC-MS/MS was operated on an electrospray ionization equipped with an ESI interface operated in positive ionization mode. The multiple-reaction monitoring (MRM) mode was used during the analytical run and it is able to quantitate up to 0.15 and 0.06 ppm of chloro and sulfide compound impurities. The newly developed method was validated as per International Conference on Harmonization (ICH) guidelines.

Keywords: Esomeprazole magnesium, Impurities, Method Validation, LC-ESI-MS/MS, Trace analysis.


[Download Article]     [Download Certifiate]

Call for Paper

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Online Submission

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Email & SMS Alert

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More