BIO-ANALYTICAL METHOD DEVELOPEMENT AND VALIDATION OF LACIDIPINE IN HUMAN PLASMA USING AMILODIPINE AS INTERNAL STANDARD BY LC/MS/MS
K. Kanaka Parvathi* and Hanumanthachar joshi
ABSTRACT
The present manuscript describes bio-analytical method developement
and validation of lacidipine in human plasma using amilodipine as
internal standard by liquid chromatography and tandem mass
spectrometry method lc/ms/ms. The column employed in this
determination was Agilent, Eclipse Zorbax XDB phenyl (4.6x75, 5μ),
mobile phase comprising 5M ammonium acetate buffer: isopropnol in
the ratio of 70:30v/v. the injection volume were 20 μL-1 the retention
time was about 1.3 for lacidipine and 0.95 minutes for Amilodipine of
a total run time of 2.5 minutes, linearity of the method was linear over
the range of 0.2052 ng/mL to 12.5026 ng/mL using Amilodipine as
internal standard.
Keywords: Lacidipine, Amilodipine.
[Download Article]
[Download Certifiate]