WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: JULY ISSUE PUBLISHED
  • JULY Issue has been successfully launched on 1 JULY 2024.

Abstract

STABILITY INDICATING METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF METFORMIN AND DAPAGLIFLOZIN BY RP-HPLC

*Ram Autar Bishwakarma, Paul Richards and Girindra Lekhi

ABSTRACT

A simple, Accurate, precise method was developed for the simultaneous estimation of the Metformin and Dapagliflozin in Tablet dosage form. The chromatogram was run through Kromasil 250 x 4.6 mm, 5. Mobile phase containing Buffer and Acetonitrile in the ratio of 60:40A was pumped through column at a flow rate of 1ml/min. Buffer used in this method was 0.1% OPA buffer and the Temperature was maintained at 30°C. Optimized wavelength for Metformin and Dapagliflozin was 266nm. The retention time of Metformin and Dapagliflozin were found to be 2.330min and 3.098 min. %RSD of the Metformin and Dapagliflozin were and found to be 0.7 and 0.8 respectively. %assay was obtained as 99.57% and 99.76% for Metformin and Dapagliflozin respectively. LOD, LOQ values are obtained from regression equations of Metformin and Dapagliflozin were 0.90ppm, 2.73ppm and 0.02ppm, 0.07ppm respectively. Regression equation of Metformin & Dapagliflozin is y = 2433.x + 15236 and y = 13061x + 672.2. Retention times are decreased and that run time was decreased so the method developed was simple and economical that can be adopted in regular Quality control test in Industries

Keywords: Metformin, Dapagliflozin, RP-HP.


[Download Article]     [Download Certifiate]

Call for Paper

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Online Submission

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Email & SMS Alert

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More