WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: NOVEMBER ISSUE PUBLISHED
  • NOVEMBER 2024 Issue has been successfully launched on NOVEMBER 2024.

Abstract

SIMULTANEOUS ESTIMATION OF SACUBITRIL AND VALSARTAN IN PHARMACEUTICAL DOSAGE FORM BY DEVELOPMENT AND VALIDATION OF STABILITY INDICATING CHROMATOGRAPHIC METHOD

Dr. C. J. Patel*, Shweta Mishra and Dr. M. M. Patel

ABSTRACT

This study aims to develop and validate a stability indicating HPLC method for simultaneous estimation of sacubitril and valsartan in pharmaceutical dosage form. Sacubitril and valsartan separation was achieved by LC- 20 AT C18 (250mm x 4.6 mm) column and buffer (potassium phosphate, pH 3.0): methanol (50:50) as mobile phase, at a flow rate of 1 ml/min (milliliter per minute). Detection was carried out at 224 nm (nanometer). The different HPLC experimental parameters were optimized and the method was validated according to standard guideline. Forced degradation experiments were carried out by exposing sacubitril and valsartan standard and sample for thermal, photolytic, oxidative and acid-base hydrolytic stress conditions. Retention time of sacubitril and valsartan were found to be 4.170 min (minute) and 6.530 min (minute) respectively. The method has been validated for linearity, accuracy, precision, LOD, and LOQ. Linearity observed for sacubitril is 12.25-36.75 μg/ml (microgram per milliliter) and for valsartan is 12.75-38.25 μg/ml (microgram per milliliter). The results showed that sacubitril and valsartan and the other degradation products were fully resolved and thus the proposed method is stability-indicating.

Keywords: Sacubitril, valsartan; RP-HPLC, stability indicating RP-HPLC method, validation.