WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: APRIL ISSUE PUBLISHED
  • April Issue has been successfully launched on 1 April 2024.

Abstract

VALIDATION STUDY FOR SIMULTANEOU ESTIMATION OF ESCITALOPRAM OXALATE AND FLUPENTHIXOL HYDROCHLORIDE IN TABLET DOSAGE FORM BY HPLC

Patel Nilam J.*, Bhumi Patel, Kaushik Patel, Jaymin Patel, Yogesh Patel and Komal Siddhanti

ABSTRACT

A simple, rapid, economical, precise and accurate Stability indicating RP-HPLC method for simultaneous estimation of Escitalopram Oxalate and Flupenthixol Hydrochloride in their combined dosage form has been developed. A reverse phase high performance liquid chromatographic method was developed for the simultaneous estimation of Escitalopram Oxalate and Flupenthixol Hydrochloride. In Their Combined Dosage form has been developed. The separation was achieved by LC- 20 AT C18 (250 mm x 4.6mm, 5 μm) column and Buffer (pH 6.5): Acetonitrile (50:50%v/v) as mobile phase, at a flow rate of 1 ml/min. Detection was carried out at 256 nm. Retention time of Escitalopram Oxalate and Flupenthixol Hydrochloride were found to be 3.423 min and 6.163 min, respectively. The method has been validated for linearity, accuracy and precision. Linearity observed for Escitalopram Oxalate (10-30μg/ml) and for Flupenthixol Hydrochloride( 0.5-1.5 μg/ml). Developed method was found to be accurate, precise and rapid for simultaneous estimation of Escitalopram Oxalate and Flupenthixol Hydrochloride.

Keywords: Escitalopram Oxalate, Flupenthixol Hydrochloride, Stability indicating RP-HPLC Method.