WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: APRIL ISSUE PUBLISHED
  • April Issue has been successfully launched on 1 April 2024.

Abstract

HIGH THROUGHPUT LC-MS/MS METHOD FOR THE QUANTITATION OF DIDANOSINE IN HUMAN PLASMA BY SOLID PHASE EXTRACTION USING 96 WELL PLATE FORMAT

Tangudu Nagabhusana Rao*, Guntuku Girija Sankar, Lade Jyothi Rani

ABSTRACT

High-throughput Liquid chromatography–mass spectrometry method has been developed and validated for the quantification of Didanosine in human plasma using Zidovudine as an internal standard (ISTD). Following solid phase extraction (SPE) in 96 well plate format, the analyte and ISTD were run on Inertsil ODS-3, 4.6 X 100 mm, 5 μm column using an isocratic mobile phase consisting of 10mM Ammonium formate buffer (pH 6.4 ± 0.5): Methanol 10:90 v/v. The precursor and product ions of the drugs were monitored on a triple quadrupole instrument operated in the positive ionization mode. The method was validated over a concentration range of 1.01 to 2002.18 ng/mL with relative recoveries ranging from 92.4 to 96.4%. The inter batch precision (%CV) across three validation runs was ≤ 8.9%. The Inter batch percent relative errors (%RE) determined at four QC levels (LLOQ, LQC, MQC and HQC) was between -7.7 to 4.9%. According to the validated results, the proposed method was found to be specific, accurate, precise and high throughput method and could be used for the estimation of Didanosine in human plasma and can be applied for the routine analysis.

Keywords: Didanosine, Zidovudine, Solid Phase Extraction and 96 well plates.