WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: APRIL ISSUE PUBLISHED
  • April Issue has been successfully launched on 1 April 2024.

Abstract

A VALIDATED REVERSE PHASE HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF GUAIFENESIN,AMBROXOL AND LEVOCETIRIZINE IN PHARMACEUTICAL DOSAGE FORMS

A.Srinivasa Rao*, K.L.N.N.S.V.K.Pavankumar, P.Satyanarayana, G. Subrahmanya Sastry

ABSTRACT

A simple, rapid, precise and accurate reverse-phase HPLC method was developed and validated for the simultaneous determination of Guaifenesin,Ambroxol and Levocetirizine in commercial tablets. The method has shown adequate separation for Guaifenesin,Ambroxol and Levocetirizine. Separation was achieved on PhenomenaxC18 (250 mm × 4.6mm; 5 µm) column using isocratic method with 0.1%OPA:Acetonitrile(60:40) system at room temperature and the detection was carried out at 290nm using photodiode array (PDA) detector. The linearity of the proposed method was investigated in the range of 50-150μg/ml (r2=0.999), 15-45μg/ml (r2=0.999), 2.5-7.5μg/ml (r2=0.999) for Guaifenesin,Ambroxol and Levocetirizine Respectively. The limit of detection (LOD) was 0.090,0.0234 and 0.012 for Guaifenesin,Ambroxol and Levocetirizine respectively. The limit of quantification (LOQ) was 0.290,0.0773 and 0.042 for Guaifenesin,Ambroxol and Levocetirizine respectively. The relative standard deviation (RSD) of six replicates is less than 2%. This HPLC method is applied successfully to the simultaneous quantitative analysis of Guaifenesin,Ambroxol and Levocetirizine in commercial tablets.

Keywords: RP-HPLC, Guaifenesine., Ambroxol, Levocetirizine.


[Download Article]     [Download Certifiate]

Call for Paper

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Online Submission

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More

Email & SMS Alert

World Journal of Pharmacy and Pharmaceutical Sciences (WJPPS)
Read More